 Buzzing sound 1Chirping noise
 Clicking noise
 Groaning sound
 Hissing sound
 
 If you have a Goodman heat pump that keeps making loud buzzing sound  even when the fan is not running and The noise goes away when you turn  move inside thermostat to off. Then its possible that the solenoid coil  is energized and making the noise. Cleaning the iron core of the  solenoid mechanism with fine sandpaper may stop the noise. If not, the  noise is harmless to the machine. If it bugs you, change the solenoid  coil. 
 If you have a chirping  noise, It is usually caused by dry bearings from low usage or age, a  fan rubbing on the coils or blower cage or a belt that needs replacing.The  best thing to do is let the unit run for a few minutes and see if it  goes away or lessens in volume or duration. If it does, note it and tell  your A/C tech when he comes out to service the unit. If it gets louder  or more constant like a squeal then turn off the unit before it does any  more damage.
 
 If your heat pump makes a loud fast clicking  noise when in heating mode. It does not do this in a/c, emergency heat,  or fan mode. Also, with every click, the thermostat dims. Then it’s a  solenoid that’s making the clicking noise.. 
 If you have a 05D-024K Single Package Heat Pump that makes a loud low groaning  sound after the main fan shut down and before the unit starts the next  heat cycle. Then there could be a blower wheel that sometimes will come  loose. It will spin inside itself and have squeal to it. The wheel is  pressed together where the inside of wheel meets the vanes. It gets  loose and makes a noise. A groaning noise on shutdown is almost always compressor.
 If your new Bryant Evolution Heat pump is making a bit of a hissing sound  in "heating" mode. Then the refrigerant lines maybe touching one of the  supply vents, and the noise is transferred and amplified. Slight  adjustment and all is taken and the noise is gone.
 |  
	
 
	
	
    
        
            | List of Noises 5:
 Knocking and Banging noisesKnocking noise 1
 Humming noise
 Sloshing/gurgling noise
 
 If you have an Amana heat pump and Honeywell VisionPRO IAQ and having problem in the defrost mode noise.
 When  it goes into defrost you can hear it shut down, and it appears to wait  only 5 seconds, if that, after the whoosh of the reversing valve before  it starts banging and clanking  as the compressor kicks back in, then since you are using your system  in the "legacy" mode, maybe you should ask your contractor about a  DFTD-1. It may save you some money over the Comfort-net thermostat.
 The  DFTD-1 kit is designed to shut the compressor off for 20 seconds when  the defrost cycle is initiated and 15 seconds at termination of the  defrost cycle. This will allow dealers to offer a Quiet Shift feature  when the unit is installed near a customer’s window or if they are  experiencing a slow shifting reversing valve. This Defrost Time Delay  Kit has demonstrated significant reduction in the compressor sound at  the initiation and termination of defrost in many installations.
 It's an add on accessory offered by Amana-Goodman to help with noise during defrost..
 
 If you have a knocking  noise - this can be a couple of things, the compressor is wearing out  or broken, the refrigerant pressures are too high or even too low, a  sticking valve in the refrigerant system, even a loose compressor can  cause this.
 
 If you have an Armstrong 17 seer heat pump that in a heat mode makes a loud humming noise from the outdoor unit when it started up and went into defrost, then it might be a bad TXV valve.
 
 If  you have a Trane X19i with XV80 indoor unit, VS motor. The coil has  TXV. When the system is in cooling mode - Stage 1, with a low load,  ambient temp lower in the evening and mornings, the liquid line makes sloshing/gurgling noise right at the coil.
 When the demand is higher - mid day, the noise is not present (still in Stage 1)
 There  is no gurgling noise in Stage 2. Then consider this - mixture of liquid  and vapor refrigerant is traveling through the line when only liquid  should be present at that point. This would cause lower capacity as the  metering device would not have a solid column of liquid refrigerant  behind it, causing flash gas. Also, overcharging it to compensate would  result in less condensing surface area resulting in the condenser acting  as a receiver equaling less efficiency.
 
 |  
	
 
	
	
    
        
            | List of Noises 6:
 Buzzing sound 2Knocking noise 2
 Buzzing noise 3
 Whining noise
 Awful noise
 Humming/buzzing noise
 
 If you have an Armstrong 18 SEER HP that when the first cold weather arrived the outdoor unit is making a buzzing    sound and the house is cold. Also it makes the sound that does kinda    sound like a jack hammer. Then if the noise sound like a jack hammer    (loud and pulsing) it's the reversing valve getting stuck somewhere in    the middle. 
 If your Rheem heat pump knocking intermittently    and it is loud and resemble a washing machine that is out of balance.    The sound seems to transfer through the Freon lines, and it’s even    louder at the outside unit. Then you should pump the system down. Take    5/16 copper tubing and make 4 loops about 12" dia. Braze this coil of    tubing in the 3/8 liquid line at the indoor unit. Evacuate and    recharge... 
 If your outside heat pump makes a continuous buzzing    noise along with a short intermittent louder/lower frequency buzz   noise  and the fan never turns, the house attic unit fan runs but the   house  never cools. Then it could be that your condenser fan motor   (outside  unit) is 'frozen up.' Bearings are probably bad and it would   be  necessary having a Service Tech check it out. Also it's possible a  fan capacitor is bad. If it is bad -   sometimes they will bulge which is a  dead giveaway that it is bad. In   which case you could take it down to  an A/C parts house and get a   replacement. If you do this - be sure all  power is off and you mark the   wires when your remove the old fan cap and  buy an exact replacement  so  you can hook it back up correctly.
 
 If your Rheem Hvac system’s the outside unit making a very loud whining    noise and the fan blades were not turning, but if you hit the reset    button and the fan blades started to turn but did not come on making a    very faint humming noise. Then it could just be the fan capacitor in  the   outside unit or the fan motor itself. Usually it is cheaper to  just   replace the capacitor first and if that does not work then  replace the   motor with the appropriate capacitor for the new motor.  
 If your Rheem dual stage heat pump is making some awful noises (watch video below) when it was set to heat, then it might the compressors internal relief valve opening and closing.And what would cause the relief valve to open and close? -   Dirty condenser coil or condenser fan spinning backwards, causing high   head pressure. So, the first thing you should check for is a dirty   filter. Second, check the indoor coil to see if it is dirty. Third make   sure all registers are open. After that if you don't find anything then   you should call a  professional.
 
 If your Carrier Infinity heat pump condenser has been making a humming/buzzing  noise when it is not running and its sounds exactly like a transformer  (like for a doorbell) then it is definitely the transformer in the  condenser.                                                                                                    Is it time to replace your heat pump? Fill out a Repair or Replace Report Card
 
 
  1 | 2 | |  
	
 | 
	
	
    
        
            | A website "ductworkinstallation. com" focus on  providing information and services related to the installation of ductwork systems , which are the tubes used to distribute heated or cooled air throughout a building as part of an HVAC system; essentially, it would be a platform for individuals or companies specializing in designing and installing ductwork for homes and commercial properties, offering details on the process, and potential contractors to contact for such services.  Key points about ductwork installation websites:  Services offered: New ductwork installation, ductwork repair, duct cleaning, duct sealing, airflow balancing.  Target audience: Homeowners looking to install a new HVAC system, individuals experiencing issues with their existing ductwork, commercial property owners needing ductwork for large buildings.  Information provided: Explanations on different types of duct materials, design considerations for optimal airflow, potential benefits of proper ductwork installation.  |  
 
	
 |